- Oxygen Therapy
- Oxygen Mask Non-rebreathing Mask Venturi Mask Tracheostomy Mask Nasal Oxygen Cannula Oxygen Connecting Tube Oxygen Device
- Circuit
- BV Filter HME Filter Heat Moisure Exchanger (HME) Circuit Set Silicone Circuit Circuit Assembles
- Hypodermic Series
- Syringe Needle Insulin Series Infusion Set Blood Transfusion Set Burette Set I.V. Cannula Blood Bag
- Surgery Series
- Skin Stapper Surgical Scalpel Electrosurgical Pencil Anesthetic Products Blood Purification Set Surgical Suture Gynecology Series Infusion Pump
- Microscope Slides Accessories
- Slides Mailer Slides Trays Slides Storage Box Slides Staining Jar Slides Staining Rack
- Hematology
- Vaccume Tube Non-Vaccume Tube Micro Blood Collection Tube Blood collection Needle Capillary Lancet Tourniquets ESR Fast Detector ESR Fast Rack Hemocytometer
- Liquid Handling
- Plastic Transfer Pipette Glass Pasteur Pipette Serological Pipet Number Fixed Reading Volume Pipette Number Reading Volume Pipette Measuring Cup Tips Bottle Washer Pipette Pump Pipette Stand Plastic Beaker Transfer Pipette Glass Biological Filter
- Sample Analysis
- Collection Swab Cuvette Cup Embedding Cassettes Microplates Sample Cup Specimen Container Cell Spreder Inoculation Loops Petri Dishes Sampling & Blender Bag
- Homecare Series
- Wheel Chair Walking Aids Nebulizers Anti-Decubitus Mattress Oxygen Generator Cervial Collar
- Diagnostic Series
- BP Appratus Stethoscope Thermometer Inspection Device Pulse Oximeter Patient Monitor & Accessories Doppler Blood Glucose Meter Others
- Hospital Equipments
- Hospital Bed & Mattress Bedside Items I.V Stand Hospital Chair Hospital Trolley Operation Lamps ECG Machine & Accessories Chair-Mounted Dental Unit Operation Table Infant Radiant Warmer Transport Incubator Suction Apparatus and Accessories Stomach Cleaning Machine X-ray Machine Anaesthetic Ventilator Ultrasound Machine & Accessories
X-Ray Machine FYS1502
Previous: Multi-function Medical Trolley FYF1306
Next: X-Ray Machine FYS1503
Product Description
X-Ray Machine
Main Usage and Features:
This x-ray appartus features fullwave rectification and
modular x-ray tube head.The frame of the unit is of
cantilever construction,and is compact in design and
easy in movement.The machine can be used for
Radiography in hospital wards or operating rooms.
Max.Ratings
Current(ma)
Voltagec(kvp)
Exposure time(second)
30
90
0.063-5.0
50
90
0.063-1.0
50
80
0.063-2.5
70
70
0.063-1.0
Main Technical Data:
1.Power requirements :
Voltage:180-240V Frequency:50HZ
Internal resistance:≤1Ω rating:5k VA
Current:Max.15A for radiography
2.Time:0.08to 6.32 steps electronic
Max. height from x-ray tube foucs to floor >1820mm
Min.height from x-ray tube foucs to floor<550mm
3.Collimator:Max. film size at 1000mm
Focal distance:430x430mm
4.Max.control distance:6m
Unit moving force:<5kg
5.N.W.:90kg
Main Usage and Features:
This x-ray appartus features fullwave rectification and
modular x-ray tube head.The frame of the unit is of
cantilever construction,and is compact in design and
easy in movement.The machine can be used for
Radiography in hospital wards or operating rooms.
Max.Ratings
Current(ma)
Voltagec(kvp)
Exposure time(second)
30
90
0.063-5.0
50
90
0.063-1.0
50
80
0.063-2.5
70
70
0.063-1.0
Main Technical Data:
1.Power requirements :
Voltage:180-240V Frequency:50HZ
Internal resistance:≤1Ω rating:5k VA
Current:Max.15A for radiography
2.Time:0.08to 6.32 steps electronic
Max. height from x-ray tube foucs to floor >1820mm
Min.height from x-ray tube foucs to floor<550mm
3.Collimator:Max. film size at 1000mm
Focal distance:430x430mm
4.Max.control distance:6m
Unit moving force:<5kg
5.N.W.:90kg